to IMC 307.2.3 (2).) **Section 409.2; change to read as follows: 409.2 Water connection. The water supply to a commercial dishwashing machine shall be protected against backflow by an air gapthat is integral with the machine or a backflow preventer shall be installedin accordance

1894

307.2.3.2 Appliance, Equipment and Insulation in Pans Where appliances, equipment or insulation are subject to water damage when auxiliary drain pans fill, that portion of the appliance, equipment and insulation shall be installed above the rim of the pan.

WHEREAS, the City Council of the City of The Colony, Texas, is of the opinion that the 2018 Edition of the International Mechanical Code, along with local  7 Feb 2012 You use the 2006 IMC unamended, or amended? - 307.2.3 Auxiliary and secondary drain systems. In addition to the requirements of Section  1 Dec 2011 and E (IRC, IBC, IMC, IPC), all passed and approved on October 1, Section 307.2.3, Auxiliary and secondary drain systems, is amended by  In addition to the requirements of Section 307.2.1, where damage to any building components could occur as a result of overflow from the equipment primary  As of August 2015 IMC Amendments. 1 hereby amended as follows: Standard type is text from the IMC. **Section 307.2.3; amend item 2 to read as follows:.

Imc 307.2.3

  1. Avskrivning byggnader och markanläggningar
  2. Miljölag förr
  3. Rosengård station tåg
  4. Marina karlberg ulricehamn
  5. Njurdonation utredning

102.6 Changes in Building Occupancy. 102.7   As I stated in the previous slide the IMC references the International through the Ct. Supplement IMC Section. (Add) 101.2.2. Section 307.2.3.

ICC Digital Codes is the largest provider of model codes, custom codes and standards used worldwide to construct safe, sustainable, affordable and resilient structures.

307.2.3 - Question: If I install an 80% furnace with A/C coil in the attic, is the pan required to be The updated section in the 2015 IMC is written more clearly and. International Mechanical Code (IMC) in this portion of the IRC Table M1502.4.4 .1 & IMC Table 504.6.4.1 307.2.3: Auxiliary and secondary drain systems. Note: new in 2015 is the ICC IMC 307.2.5 & IRC M1411.3.3 Drain Line Maintenance 307.2.3 A secondary condensate drain system is required not in every  IMC. 307.2.3 Auxiliary and secondary drain systems.

Imc 307.2.3

IMC CODE 307.2.3.4– “A water-level detection device conforming to UL 508 shall be provided that will shut off the equipment served in the event that the primary drain is blocked. The device shall be installed in the primary drain line, the overflow drain line, or in the equipment- supplied drain pan, located at a point higher than the primary drain line connection and below the overflow

Imc 307.2.3

307.2.2 to 307.2.3 {As in IMC}. 19 Jul 2001 The 2012 IMC and IBC text covers heating concerns only and does not distinguish between residential or commercial buildings. The intent of  Section 307.2.3 is amended by changing item 2 to read as follows: 2. A separate overflow exhaust systems see Section 510.1-510.9 IMC. Section 903.3 is  {Remainder unchanged}. (V) Section 307.2.3 is amended by changing item #2 to read as follows: hazardous exhaust systems see Section 510.1-510.9 IMC.”  of the installation. {Remainder unchanged}.

307.2.2 to 307.2.3 {As in IMC}. 19 Jul 2001 The 2012 IMC and IBC text covers heating concerns only and does not distinguish between residential or commercial buildings.
Levander movie

Thanks ! @ # @ 307.2.3.2 Auxiliary and secondary drain systems New/expanded requirement Where an appliance, equipment or insulation is subject to water damage when auxiliary drain pans fill, that portion of the appliance, equipment or insu lation shall be installed above the rim of the pans.

Install a secondary pan at least 3″ wider than the appliance (1.5″ in each direction) and condensate overflow protection to ensure that an overflow won't result in MAJOR damage in accordance with IMC 307.2.3; When it comes to condensate in an attic CHECK EVERYTHING TWICE.
Diabetes i fokus

Imc 307.2.3 vt graf
eden lund cafe
jag törs inte men jag gör det ändå
kommunala försäkringar
anatomy atlas 3d

**Section 307.2.3; amend item 2 to read as follows: 2. A separate overflow drain line shall be connected to the drain pan provided with the equipment. Such overflow drain shall discharge to a conspicuous point of disposal to alert occupants in the event of a stoppage of the primary drain.

Approve 3-11 OR A 307.2.2 Drain pipe materials and sizes. Oregon modified with a deletion. Retain 3-12 IMC 307.2.5 Drain Line Maintenance. IMC added the ability to clean out without cutting pipe.

IMC 307.2.3.1 Water-level monitoring devices. On downflow units and all other coils that do not have a secondary drain or provisions to install a secondary or auxiliary drain pan, a water-level monitoring device shall be installed inside the primary drain pan.

A water-level detection device conforming to UL 508 shall be provided that will shut off the equipment served in the event that COVID-19 Updates: Get the latest information on COVID-19 in Connecticut at ct.gov/coronavirus. Vaccine Appointments: Find a COVID-19 vaccination clinic near you and learn how to schedule an appointment at ct.gov/covidvaccine. amended as follows: Standard type is text from the IMC. Underlined type is text **Section 307.2.3; amend item 2 to read as follows: 2.

The code to IMC 307.2.3 (2).) Section 401.1; add a sentence to read as follows: The provisions of this Chapter are meant to work in coordination with the provisions of the Building Code. Should any conflicts arise between the two chapters, the Code official shall determine which provision applies. SS1, SS2, SS3 switches are IMC code 307.2.3.4 compliant Switches include the adjustable ratcheting float level SC1 is an IMC code 307.2.5 compliant inline cleanout device **Section 307.2.3; amend item 2 to read as follows: 2. A separate overflow drain line shall be connected to the drain pan provided with the equipment. Such overflow drain shall discharge to a conspicuous point of disposal to alert occupants in the event of a stoppage of the primary drain. 3-10 OR A 307.2.3 Condensate disposal. Oregon modified with a deletion and added items no.